What is the difference between Fisher 67CFR and 67CF?
Fisher 67CF and 67CFR Functional Differences
| Item | 67CF | 67CFR |
|---|---|---|
| Internal Relief Valve | Not included | Included (soft-seat, bubble-tight shutoff) |
| Overpressure Protection | Relies only on external devices | Handles minor internal leakage; external protection still recommended |
| Smart Bleed™ Option | Not available | Available |
| Fixed Bleed Restriction | Not available | Available |
| Downstream Pressure Control | Basic regulation + filtration | Regulation + filtration + overpressure relief + fail-safe venting |
Common Functions & Specifications
Detailed Functional Notes
Internal Relief (Critical Difference)
- 67CF: No internal relief. Downstream overpressure must be controlled by external relief or limiting devices.
- 67CFR: Soft-seat internal relief opens if outlet pressure exceeds setpoint, prevents overpressure and conserves air.
Smart Bleed
- 67CF: Not supported.
- 67CFR: Optional internal check valve that vents downstream pressure if inlet pressure drops below setpoint, ideal for fail‑safe actuators and dead‑end service.
Air Consumption
- 67CF: Zero air loss under normal operation.
- 67CFR: Zero air loss in lockup; vents only during overpressure or inlet failure.
Introduction of Xi 'an Lilu Trading Co., LTD
Xi 'an Lilu Trading Co., Ltd. is a professional import and export focus on transmitter, flow meter, positioner instrument industry provider. We have a huge advantage in the following brand ROSEMOUNT, YOKOGAWA, HONEYWELL, SMC, IMI NORGREN, ABB, ENDRESS + HAUSER, FISHER, YTC, AZBIL, SIEMENS, SCHNEIDER and some European brands.